Services

Mechanical, electrical and
plumbing — schematic design
through record drawings.

Scoped by discipline and by design phase, so you can price us into your own proposal
without a call. Where we don’t cover something, we say so plainly.

Coverage

Every MEP discipline, every phase

Discipline

SD

DD

CD

Permit

Submittals & RFIs

Record drawings

Mechanical

Electrical

Plumbing

All three disciplines engineered in-house by our own staff. Site visits and field verification stay with your firm — see below.

Scope detail

What's included, by discipline

Mechanical/HVAC

Commercial loads in Carrier HAP Residential Manual J, D and S in Elite RHVAC Equipment selection and schedules Duct layout, sizing, static pressure Hydronic piping layout and sizing Ventilation to ASHRAE 62.1 Details, sections, sequences of operation Demolition and phasing plans

Electrical

Load calcs to NEC Article 220 Service and feeder sizing, one-lines Panel schedules, connected and demand Voltage drop and short-circuit checks Lighting with photometrics to IES Egress, emergency, legally required standby Low-voltage, fire alarm device layouts Solar PV layouts and interconnection detailing

Plumbing

Fixture units and sizing per IPC / UPC Domestic water pressure and pump calcs Sanitary, vent and storm layouts Riser diagrams, fixture schedules Storm sizing to local rainfall intensity Natural gas load and sizing Water heater sizing, specialty piping

Also included in a CD scope

Drawing index and sheet setup · Demolition and phasing plans · Specifications in CSI MasterFormat three-part sections, or as short-form notes on the drawings — whichever your office uses · Deferred submittal coordination · General notes, legends and abbreviation sheets

Specialist studies

Power systems studies — the electrical work most firms sub out

Modeled, run and reported by our own electrical engineers. If you already send this work outside your firm, you’re
only changing who does it.

Studies we produce

Short circuit and fault current analysis
Protective device coordination
Arc flash hazard analysis to IEEE 1584 and NFPA 70E, with equipment labels
Harmonic analysis to IEEE 519

Also available

Motor starting and voltage dip
Selective coordination for emergency and legally required systems
Grounding studies
Load flow and capacity checks

What we need from you

Field data collection and the utility fault current letter. Since we don't attend site, equipment nameplate data, conductor lengths and one-line verification come from your team. We build the model, run the study, and produce the report and labels for your review and seal. Study method and software are confirmed in the proposal; where you need native SKM output, we work on your seat with your written authorization.

Healthcare

Healthcare — the work most outsourcing firms won’t take

Healthcare is unforgiving and the review process is its own discipline. We take it because our founder spent seven years at IMEG Corp’s India office with roughly 95% of his work on healthcare, including HCAI and OSHPD projects, and every healthcare package gets senior review.

Mechanical

Pressure relationships, air changes and filtration to FGI Guidelines and ASHRAE 170 In California, to CMC Chapter 4, Table 4-A — which adopts ASHRAE 170 with state amendments Isolation and protective environment rooms, with pressure monitoring Operating room and procedure space ventilation

Electrical

Essential electrical systems to NFPA 99 and NEC Article 517 Type 1 systems — life safety, critical and equipment branches Generator and transfer switch arrangement Patient care space classification

Plumbing and medical gas

Medical gas and vacuum to NFPA 99 Zone valve boxes, area alarms and outlet counts by space type Source equipment sizing and manifold arrangement Sanitary, sterilizer and lab waste separation

Review and coordination

HCAI and OSHPD submittal documentation and back-check responses Seismic anchorage and bracing coordination, including preapproved details Infection control risk assessment coordination and phasing plans Above-ceiling coordination in tight interstitial space

We produce the documentation. Your PE remains engineer of record, files with HCAI or your AHJ, and handles anything requiring an Inspector of Record or a site presence. On existing-facility work we can sequence and detail a tie-in, but the field verification behind it comes from your team.

Energy compliance

Energy code compliance, in all fifty states

Most jurisdictions run IECC or ASHRAE 90.1, and we submit COMcheck on the prescriptive path or model the performance path. Where a state runs its own regime we work in that instead. The adopted edition and its local amendments are confirmed in the proposal before we start, and the completed forms are issued with the set for your seal.

Most states — IECC and ASHRAE 90.1

COMcheck on the prescriptive path, or the performance path via energy modeling. Envelope, mechanical and interior lighting compliance forms, prepared to the edition your jurisdiction has adopted.

Florida energy code in EnergyGauge

Title 24 Part 6 documentation. Certificates of compliance for mechanical, indoor lighting and envelope, prepared in EnergyPro on our own license.

States running their own regime

Florida Building Code Energy Conservation forms, prepared in EnergyGauge, Washington’s WSEC, New York’s stretch code, and the state amendments in place elsewhere. Tell us the jurisdiction and we confirm in writing what we can produce before you commit.

Local amendments and stretch codes are confirmed at proposal stage. If your jurisdiction runs its own forms, tell us before you commit and we’ll confirm in writing whether we can produce them.

After issue

We don’t disappear at CD

The weeks after a set is issued are when most firms need help and most outside teams have already
moved on. We stay on the project.

Submittal review

Equipment submittals and shop drawings checked against the specified basis of design and the schedules. Marked up with exceptions noted, returned for your sign-off.

RFI responses

Drafted responses with the revised detail or sketch attached. Where an RFI turns on field conditions, you supply the observation and we draft from it.

Plan review comments

AHJ comments addressed, drawings revised, deferred submittals coordinated, and a response letter drafted for your review and signature.

Everything here is drafted for your review and issued under your seal. You remain the decision-maker on every response; we do the work behind it.

Fire protection, civil and structural — when you need it bundled

Fire protection

Civil

Structural

Delivered through a vetted extended team, contracted and managed by us as a single NexMEP scope with one point of contact and one invoice. MEP remains our in-house discipline.

What we don't do

Every one of these stays with your firm, where the license and the liability already sit. If a scope needs
something on this list, tell us early and we’ll say plainly that it isn’t ours.

Software

What we own and run in-house

Modeling

Revit 2023–2027
Save-down supported Navisworks Manage

Drafting

AutoCAD 2018–2027
Civil 3D
Native DWG or DXF back

Calculations

Carrier HAP
Elite, AGi32
COMcheck, EnergyPro

Collaboration

Autodesk Construction Cloud
BIM 360
Bluebeam Revu

All of the above are licensed to NexMEP, so no license exposure passes to your firm. Where a project calls for a platform your
firm standardizes on, we work on your license with your written authorization. Still on an older release? Tell us the version and we’ll match it.

Turnaround

Typical schedule, full MEP CD set

Project size

Sheets

Schedule

Tenant improvement, under 10,000 sf

3 / 4 / 3  =  8–14

2–3 weeks

Commercial, 10,000–50,000 sf

7 / 9 / 6  =  18–30

3–5 weeks

Mid-rise or healthcare, 50,000–150,000 sf

15 / 20 / 12  =  35–60

6–10 weeks

High-rise or complex program

60+

Quoted per project

Sheet counts are typical for a full M+E+P construction document set and vary with system complexity. These are typical, not fixed. Every project and every office works differently, so lead with the date you need and we will tell you within four working hours whether we can hold it. Standard schedules assume complete architectural backgrounds at kickoff. Expedited work displaces other jobs, is priced accordingly, and depends on current capacity — ask rather than assume.

Standalone scopes

Scope

Typical turnaround

Short circuit and coordination study

2–3 weeks from receipt of field data

Arc flash analysis with labels

3–4 weeks from receipt of field data

COMcheck compliance forms

3–5 business days with a complete set

Title 24 Part 6 documentation

1–2 weeks

Submittal review

2–3 business days per submittal

COMcheck compliance forms

3–5 business days with a complete set

RFI response

1–2 business days

What a typical sheet set contains

Numbering follows your convention. This is the structure we work to where you don’t have one.

Mechanical

M-001 Legend and general notes
M-101 Floor plans
M-201 Roof and mechanical room plans
M-301 Sections and details
M-401 Equipment schedules
M-501 Control diagrams and sequences

Electrical

E-001 Legend and general notes
E-101 Lighting plans
E-201 Power plans
E-301 Systems and low-voltage plans
E-401 One-line diagram E-501 Panel schedules
E-601 Details

Plumbing

P-001 Legend and general notes
P-101 Underground and sanitary plans P-201 Domestic water and gas plans
P-301 Riser diagrams
P-401 Schedules and details

Getting started

What we need from you to quote and start

For a lump-sum fee within 24 hours, the first three are enough. The rest we collect at kickoff.

To quote

At kickoff

Send us a set of drawings.

You’ll have a lump-sum proposal within 24 hours. No call required first, and a
mutual NDA is available before you send anything.

+1 (512) 294 9865 ·  Calls mornings or evenings, Central — your choice