FIRE PROTECTION ENGINEERING

Standpipe Systems

Vertical standpipe riser and hose connection production support coordinated with your engineer’s fire department access design.

Our Founding and Mission

Introduction

NexMEP Global LLC supports U.S. MEP consulting firms with standpipe system production, developing vertical riser layouts, hose connection locations, and system class documentation from your engineer’s design basis and the fire department access strategy established for the project. Our team carries standpipe layout through each design phase while your licensed fire protection engineers retain full authority over system class selection, pressure requirements, and code compliance approach.

We work from the standpipe class, hose connection locations, and pressure design basis your engineer provides, producing coordinated documentation that reflects that design intent accurately, consistent with the coordination this vertically distributed system requires across every floor of a building. Because standpipes exist specifically to support fire department hose operations, our documentation is built with the level of clarity a responding fire department, as well as the plan reviewer, needs to rely on it.

DESIGN ACCURACY & COMPLIANCE

Why This Service Matters

Standpipe systems exist to support fire department operations during an emergency, which means hose connection locations, pressure availability, and system class must be documented with precision the fire marshal will verify closely during plan review. Because standpipes run the full height of a building and typically share riser shafts with sprinkler piping, domestic water piping, and other vertical systems, coordinating standpipe routing without conflicts requires attention from the earliest design phase.

Production support allows this vertically repetitive but detail-sensitive documentation to be developed consistently floor to floor, reducing the risk that a coordination conflict on one level goes unnoticed because it was resolved differently on a similar level elsewhere in the building. A standpipe system that is inconsistent from floor to floor also complicates fire department familiarity with the building during an actual emergency response, which is a real-world consequence beyond the plan review process itself.

Our Capabilities

Vertical Riser & Shaft Routing

Multi-story riser layouts aligned across shaft spaces and structural penetrations.

Hose Connection Placement

Precise placement coordinated with stair enclosures, corridor layouts, and fire access paths.

Pressure-Reducing Valve Zones

Detailed zone mapping and valve documentation for high-rise pressure control.

Phased Construction Sequencing

Documenting active riser operations for occupied zones during ongoing construction.

Local AHJ & FDNY Alignment

Integrating jurisdiction-specific fire department connection (FDC) and hose valve requirements.

Floor-by-Floor Consistency

Standardized typical floor configurations to ensure clear, error-free field installation.

Calculations

Engineering Calculations

Calculation methodology built for accurate, traceable HVAC equipment sizing.

Flow & Pipe Sizing Backup

Riser sizing consistent with Class I, II, or III flow requirements and remote outlet demand.

Pressure Zone & Hydraulic Alignment

Pressure-reducing valve calculations keeping hose connection pressure within code limits, coordinated with sprinkler demand.

Calculations

Systems We Support

Ventilation-related calculation support includes outdoor air rate compilation.

Class I Systems

2½-inch hose connections for trained fire department personnel.

Class II Systems

1½-inch hose stations designed for occupant or first-aid use

Class III Systems

Combined systems featuring both 1½-inch and 2½-inch hose outlets.

Wet & Dry Standpipes

Automatic wet, manual dry, and automatic dry configurations.

Combined Sprinkler/Standpipe Risers

Integrated vertical piping networks sharing common supplies.

Occupancy Transition Zoning

Custom Class and pressure strategies across mixed-use tower boundaries.

Our production capabilities support life-safety infrastructure across complex architectural forms, delivering clear riser documentation for everyday plan checks and emergency response clarity.

Calculations

Software, Workflow & Coordination

Rigorous backup calculations formatted directly for permit submission and QA/QC documentation.

Software & Production Workflow

Modeled in Revit MEP and AutoCAD using your firm’s standards. Shaft routing is synchronized with architectural stair cores early in design, supported by a floor-by-floor consistency check to lock down typical layouts.

Revit & AutoCAD Coordination

Shaft distribution is coordinated against structural framing and MEP utilities using Navisworks. We verify hose valve accessibility, door clearances, and visibility at every stair landing to avoid unexpected site conditions.

Calculations

Systems We Support

Expertise across diverse equipment lines, hybrid configurations, and complex Electrical setups.

Standpipe Riser Schematics

Hose Connection Floor Plans

Pressure Control Packages

Calculation Backup Reports

Need High-Rise Standpipe & Life-Safety Modeling Capacity?

Partner with NexMEP Global LLC for coordinated vertical riser diagrams and permit-ready standpipe plans.

Our Core Philosophy

Typical Project Types

High-Rise Commercial & Residential

Office towers, luxury high-rises, and mixed-use developments.

Healthcare & Institutional

Multi-story hospitals, clinical towers, and academic facilities.

Mid-Rise Multifamily

Podiums, mid-rise apartments, and student housing developments.

Phased Retrofits & Upgrades

Standpipe modifications maintaining active service in occupied buildings.

Calculations

QA/QC Process

A rigorous, multi-tiered review structure ensuring accurate, clear, and error-free submittals.

Class & Sizing Verification

Confirming riser sizes and hose connection classes conform strictly to engineering parameters.

Pressure Boundary Cross-Checks

Secondary checks ensuring pressure-reducing valves match across plans, risers, and calculations.

Floor-to-Floor Consistency Audits

Rigorous reviews auditing stair core layouts to eliminate vertical variations across typical floors.

Why NexMEP Global LLC?

NexMEP Global LLC brings a dedicated production team with practical experience across standard and specialty ventilation systems, a consistent U.S. code and standards focus, and a multi-level QA/QC process that reduces rework during your engineer’s review cycle.